Patients with absent or ineffective breathing may have cyanosis, visible retractions, severe use of accessory muscles, altered mental status, respiratory rate less than 12 breaths per minute, signs of poor perfusion
All levels
Open the airway using the head-tilt/chin-lift or modified jaw-thrust maneuver
Remove any visible airway obstruction by hand
Clear the airway of any accumulated secretions or fluids by suctioning
Provide positive pressure ventilation using an appropriate size bag-valve-mask (BVM)
Use of level-appropriate airway adjuncts and bag-valve-mask (BVM), as indicated, with BLS airway management, including suction (as needed), as available
The bag-valve-mask (BVM) should be connected to supplemental oxygen, if available
Ventilate every 3-5 seconds
Each breath is given over 1 second and should cause visible chest rise
Attach pulse oximeter if available and have a goal of oxygen saturation ≥92%