Oxygen Administration and Airway Management
Applies to adult and pediatric patients
Criteria
- Providers may operate as outlined below. They may not exceed their scope of practice, even with direct online medical control.
All levels
- Ongoing assessment of the effectiveness of breathing
- See as necessary Respiratory Arrest / Failure – Adult or Respiratory Arrest / Failure – Pediatric
- Oxygen therapy via non-rebreather mask 10-15 LPM, or nasal cannula 2-6 LPM, to maintain oxygen saturation if saturation is <92% or to effectively manage other signs of dyspnea
- Some children with cardiac conditions may have baseline oxygen saturations between 65 and 85% rather than above 92% (ask care provider about patient’s usual oxygen saturation level)
- Infant oxygen administration, if needed, should be provided at 0.5-2 LPM via appropriately sized nasal cannula
- Any patient with suspected carbon monoxide poisoning should receive high flow oxygen via non-rebreather mask, see Carbon Monoxide Exposure – Suspected
- Oxygen therapy using bag-valve-mask 15-25 LPM
- Appropriate BLS airway adjuncts
- Bag-valve-mask assisted ventilation
EMT and up
- Oxygen powered nebulizer devices for use in accordance with manufacturer specifications (typically ~6-8 LPM)
- Continuous positive airway pressure (CPAP)‡ 5-10 cm H2O for the adult patient or older pediatric patient as equipment size allows
- Supraglottic airway placement‡ in the cardiac arrest patients (as regionally approved)
- Consider PEEP 5 cm H20 titrated up to 10 cm H2O
- Portable automated transport ventilators (ATV)‡, see Automatic Transport Ventilator
AEMT and up
- Supraglottic airway placement in unresponsive patients
CC and up
- Oral endotracheal intubation in ADULTS
- Age-appropriate laryngoscope and Magill Forceps in cases of obstructed airway
Paramedic
- Nasal endotracheal intubation in ADULTS‡ if regionally credentialed
- Pediatric intubation
- Consider intubation in pediatric patients only if unable to effectively ventilate with bag-valve-mask (BVM) and basic airway adjuncts
- Rapid sequence intubation‡ if regionally credentialed
- Surgical airway‡
Medical control
- Additional PEEP >10 cm H2O provided MAP maintained >65 mmHg
Key points
- Oxygen should be titrated to maintain saturation at or just above 92% and/or to treat signs of dyspnea. If there is a situation in which the patient may be unstable and hypoxia might be missed (such as major trauma), it is acceptable to place the patient on high flow oxygen.
- Blow-by oxygen administration may be required in some cases
- Providers may only place an endotracheal tube or supraglottic airway if they utilize waveform capnography for initial and ongoing monitoring of airway patency
- Only paramedics may intubate pediatric patients
- Rapid sequence intubation is to be performed only by paramedics who have received specific training and are approved per regional procedure
- Only air medical agencies may perform pediatric rapid sequence intubation on standing orders
- Intubation may be attempted on a patient a maximum of 2 times by one provider, and one more time by a second, if appropriate. If a patient is not intubated for any reason, utilize an alternative airway device and ventilate with a bag-valve-mask (BVM).
- A cervical collar should be considered on all intubated patients to assist the maintenance and secure placement of the airway device, especially when moving the patient
- Approved list of alternative airway devices is available through each Regional Program Agency
- Contraindications for use of alternative airway device:
- Patients with pharyngeal hemorrhage, tracheostomy, or laryngectomy
- Patients who have ingested a caustic substance
- Patients with known obstruction of larynx and/or trachea
- BiPAP may be used in place of CPAP, as training and equipment allow