Oxygen Administration and Airway Management

Applies to adult and pediatric patients

Criteria

  • Providers may operate as outlined below. They may not exceed their scope of practice, even with direct online medical control.

All levels

  • Ongoing assessment of the effectiveness of breathing
  • See as necessary Respiratory Arrest / Failure – Adult or Respiratory Arrest / Failure – Pediatric
  • Oxygen therapy via non-rebreather mask 10-15 LPM, or nasal cannula 2-6 LPM, to maintain oxygen saturation if saturation is <92% or to effectively manage other signs of dyspnea
  • Some children with cardiac conditions may have baseline oxygen saturations between 65 and 85% rather than above 92% (ask care provider about patient’s usual oxygen saturation level)
  • Infant oxygen administration, if needed, should be provided at 0.5-2 LPM via appropriately sized nasal cannula
  • Any patient with suspected carbon monoxide poisoning should receive high flow oxygen via non-rebreather mask, see Carbon Monoxide Exposure – Suspected
  • Oxygen therapy using bag-valve-mask 15-25 LPM
  • Appropriate BLS airway adjuncts
  • Bag-valve-mask assisted ventilation

EMT and up

  • Oxygen powered nebulizer devices for use in accordance with manufacturer specifications (typically ~6-8 LPM)
  • Continuous positive airway pressure (CPAP)‡ 5-10 cm H2O for the adult patient or older pediatric patient as equipment size allows
  • Supraglottic airway placement‡ in the cardiac arrest patients (as regionally approved)
  • Consider PEEP 5 cm H20 titrated up to 10 cm H2O
  • Portable automated transport ventilators (ATV)‡, see Automatic Transport Ventilator

AEMT and up

  • Supraglottic airway placement in unresponsive patients

CC and up

  • Oral endotracheal intubation in ADULTS
  • Age-appropriate laryngoscope and Magill Forceps in cases of obstructed airway

Paramedic

  • Nasal endotracheal intubation in ADULTS‡ if regionally credentialed
  • Pediatric intubation
  • Consider intubation in pediatric patients only if unable to effectively ventilate with bag-valve-mask (BVM) and basic airway adjuncts
  • Rapid sequence intubation‡ if regionally credentialed
  • Surgical airway‡

Medical control

  • Additional PEEP >10 cm H2O provided MAP maintained >65 mmHg

Key points

  • Oxygen should be titrated to maintain saturation at or just above 92% and/or to treat signs of dyspnea. If there is a situation in which the patient may be unstable and hypoxia might be missed (such as major trauma), it is acceptable to place the patient on high flow oxygen.
  • Blow-by oxygen administration may be required in some cases
  • Providers may only place an endotracheal tube or supraglottic airway if they utilize waveform capnography for initial and ongoing monitoring of airway patency
  • Only paramedics may intubate pediatric patients
  • Rapid sequence intubation is to be performed only by paramedics who have received specific training and are approved per regional procedure
  • Only air medical agencies may perform pediatric rapid sequence intubation on standing orders
  • Intubation may be attempted on a patient a maximum of 2 times by one provider, and one more time by a second, if appropriate. If a patient is not intubated for any reason, utilize an alternative airway device and ventilate with a bag-valve-mask (BVM).
  • A cervical collar should be considered on all intubated patients to assist the maintenance and secure placement of the airway device, especially when moving the patient
  • Approved list of alternative airway devices is available through each Regional Program Agency
  • Contraindications for use of alternative airway device:
  • Patients with pharyngeal hemorrhage, tracheostomy, or laryngectomy
  • Patients who have ingested a caustic substance
  • Patients with known obstruction of larynx and/or trachea
  • BiPAP may be used in place of CPAP, as training and equipment allow
Collaborative 26.2 · pp. 171–172BLS version