Cardiac Arrest – Pediatric: General Approach Criteria For patients who are unresponsive without signs of life For patients that do not meet the criteria of the Obvious Death protocol or otherwise excluded by a DNR/MOLST order, see “Advance Directives/MOLST/DNR” See Environmental: Hypothermia if there is concern for severe/profound hypothermia All levels CPR should be initiated prior to defibrillation unless the cardiac arrest is witnessed by the responding EMS provider Perform compressions while awaiting the application of defibrillation pads Push hard and fast (100-120 compressions/min) Metronome or feedback devices are strongly encouraged Ensure full chest recoil Minimize interruptions in chest compressions Cycle of CPR = 30 compressions then 2 breaths (single rescuer)
15 compressions then 2 breaths (if two rescuers available) 5 cycles ≈ 2 minutes (10 cycles ≈ 2 minutes for 2-rescuers) Rotate compressors every two minutes with rhythm checks, as resources allow Minimize interruptions in chest compressions Avoid hyperventilation Use of level-appropriate airway adjuncts and bag-valve-mask (BVM), as indicated, with BLS airway management, including suction (as needed) Rhythm check or AED “check patient” every two minutes of CPR Defibrillate as appropriate (pediatric pads preferred for children with weight <25 kg or age <8 years, if available) Resume CPR immediately after defibrillation (do not check a pulse at this time) Continue CPR for approximately 2 minutes cycles before doing a pulse check, or until the patient no longer appears to be in cardiac arrest AEMT and up See also rhythm-specific protocols Paramedic Consider intubation only if unable to effectively ventilate with a bag-valve-mask (BVM) and basic airway adjuncts Higher levels Medical control Termination of resuscitation in instances that are not covered by standing order criteria may be authorized by medical control Key points Intubation is not necessary if oxygenating and ventilating patient well with BLS airway management Do not interrupt compressions for placement of an advanced airway Minimize interruption in compressions for placement of a mechanical CPR device Do not delay beginning compressions to begin ventilations Do not delay ventilations to connect supplemental oxygen Adequate ventilation may require disabling the pop-off valve if the bag-valve-mask (BVM) if so equipped AED should be placed as soon as possible without interrupting compressions to do so If a patient has a medication patch, it may be removed (use appropriate PPE) Artifact from vibrations in a moving ambulance may compromise the effectiveness of the AED Consider calling medical control for termination of resuscitation or initiation of transport after 20 minutes of CPR Compressions in moving ambulances pose a significant danger to providers, are less effective, and should be avoided Consider mechanical CPR devices when available for provider safety, if there is a need to do compressions in moving ambulances Note: The use of a particular mechanical CPR device may be contraindicated in the pediatric patient; refer to manufacturer’s recommendation