Cardiac Arrest – Adult: General Approach

For pediatric see, Cardiac Arrest – Pediatric: General Approach

Criteria

  • For patients who are unresponsive without signs of life
  • For patients that do not meet the criteria of the Extremis: Obvious Death protocol or otherwise excluded by a DNR/MOLST order, see “Resources: Advance Directives/MOLST/DNR”
  • See Environmental: Hypothermia if there is concern for severe/profound hypothermia

All levels

  • CPR should be initiated prior to defibrillation unless the cardiac arrest is witnessed by the responding EMS provider
  • Perform compressions while awaiting the application of defibrillation pads
  • Push hard and fast (100-120 compressions/min)
  • Metronome or feedback devices are strongly encouraged
  • Ensure full chest recoil
  • Minimize interruptions in chest compressions
  • Cycle of CPR = 30 compressions then 2 breaths
  • 5 cycles ≈ 2 minutes
  • Rotate compressors every two minutes with pulse checks, as resources allow
  • Minimize interruptions in chest compressions
  • Continuous compressions with asynchronous ventilation (not stopping compressions while ventilating) is permitted to substitute for cycles of CPR that have pauses for ventilation even in non-intubated patients
  • Avoid hyperventilation (breathing too quickly or deeply for the patient)
  • Use of airway adjuncts and bag-valve-mask (BVM), as indicated, with BLS airway management, including suction (as needed),
  • Rhythm check or AED “check patient” every 5 cycles or two minutes of CPR
  • Defibrillate as appropriate
  • Resume CPR immediately after defibrillation (do not check a pulse at this time)
  • Continue CPR for approximately 2 minutes cycles before doing a pulse check, or until the patient no longer appears to be in cardiac arrest
  • Consider vector change for refractory shockable rhythms¹

EMT and up

  • After 20 minutes without achieving ROSC, consider calling medical control for: termination of resuscitation, continuing efforts, or (only in extenuating circumstances) transportation

Medical control

  • Termination of resuscitation in instances that are not covered by standing order criteria may be authorized by medical control

Key points

  • 1 – A vector change refers to altering the placement of the defibrillation pads (e.g. changing from sternum/apex to anterior/posterior). A refractory shockable rhythm means that multiple shocks were given and the patient is suspected to remain in a pulseless, shockable rhythm such as VF or pulseless VT.
  • Minimize interruption in compressions for placement of a mechanical CPR device
  • Do not delay beginning compressions to begin ventilations
  • Do not delay ventilations to connect supplemental oxygen
  • Adequate ventilation may require disabling the pop-off valve if the bag-valve-mask (BVM) if so equipped
  • AED should be placed as soon as possible without interrupting compressions to do so
  • If a patient has a medication patch, it may be removed (use appropriate PPE)
  • Vibrations in a moving ambulance may compromise the effectiveness of the AED
  • Compressions in moving ambulances pose a significant danger to providers, are less effective, and should be avoided
  • Consider mechanical CPR devices when available for provider safety if there is a need to do compressions in moving ambulances