Vascular Devices – Pre-Existing
Applies to adult and pediatric patients
Paramedic
- Procedure
- Identify the device
- If the patient is in EXTREMIS and a lifesaving intervention will be performed, establish access to the device
- If the patient is not in extremis, consult medical control for orders to access the device
- No prophylactic IV lines / access may be established using pre-existing vascular devices
- Procedure to establish access to Pre-Existing Vascular Access Device:
- Discontinue any solution flowing into the pre-existing vascular device (providing continuous infusion is not necessary to maintain such as Epoprostenol [Flolan]; contact medical control in these cases prior to initiating access)
- Put on sterile gloves, if available
- Clean injection site with iodine solution or chlorhexidine wipe. Do not remove or unscrew the cap, unless no other means of accessing the device is possible.
- Remove any clamps on the vascular access device, and slowly withdraw 10 mL of fluid from the port
- Inject 5 mL normal saline. If the bolus does not inject freely, the access must not be used.
- If the device is patent, inject the remaining 5 mL from the syringe
- Secure an administration set to the access site
- Maintain Normal Saline KVO through the device
- Administer a fluid bolus and/or medications as you would for a peripheral IV
- If the access device is damaged and begins to leak, clamp it one inch from the skin entry site with a padded, non-serrated hemostat, if available
Key points
- EXTREMIS includes, but is not limited to: cardiac arrest, respiratory arrest, status epilepticus, decompensated shock, and life threatening arrhythmias
- Pre-existing vascular devices include central venous catheters (CVC), peripheral inserted central catheters (PICC), and renal dialysis lines (NOT fistulas)
- Implanted ports and fistulas are not considered pre-existing vascular devices, and cannot be accessed by the prehospital provider
- Percutaneous catheters below the nipple are not for vascular access and should not be used
- Once the device is accessed, continuous flow of Normal Saline must be maintained